Back to top
Laminar Flow Apparatus
Laminar Flow Apparatus

Laminar Flow Apparatus

MOQ : 1 Unit

Laminar Flow Apparatus Specification

  • Accuracy
  • HEPA Filter 99.97% up to 0.3 micron
  • Display Type
  • No Display
  • Glass Type
  • Acrylic Transparent Front Panel
  • Control Type
  • Manual Switch Control Panel
  • Power Supply
  • Single Phase
  • Features
  • HEPA Filter, Pre-Filter, UV Light, Fluorescent Light, Low Noise Level
  • Shape
  • Rectangular
  • Temperature Resistance
  • Upto 50C
  • Speed Range
  • Variable 0.3 - 0.5 m/s Air Flow
  • Type
  • Horizontal Laminar Flow Cabinet
  • Dimension (L*W*H)
  • 1200 x 600 x 600 mm
  • Equipment Type
  • Lab Air Purification System
  • Equipment Materials
  • MS Powder Coated & Stainless Steel
  • Power
  • 220V AC, 50Hz
  • Voltage
  • 220 V
  • Material
  • Stainless Steel and Mild Steel
  • Application
  • Laboratory, Pharmaceutical, Microbiology, Research
  • Capacity (Ltr)
  • Suitable for 2-3 persons working area
  • HEPA Filter Grade
  • H14 (EN 1822)
  • Air Cleanliness Level
  • Class 100 (ISO 5)
  • Noise Level
  • Less than 65 dB
  • Blower Motor
  • Dynamically Balanced, Low Vibration
  • Work Surface Material
  • Stainless Steel 304 Grade
  • Lighting
  • UV Germicidal Tube and White Fluorescent Lamp Included
  • Pre-Filter
  • Washable Synthetic Fiber
  • Pressure Gauge
  • Magnehelic gauge for filter pressure reading
  • Front Door
  • Transparent Acrylic Sash Sliding
  • Mobility
  • Caster Wheels Provided for Easy Movement
 

Laminar Flow Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 7-10 Days
  • Main Domestic Market
  • All India
 

About Laminar Flow Apparatus



Discover unassailable value with this world-class Laminar Flow Apparatus, engineered for laboratory excellence. Featuring a rare H14-grade HEPA filter (EN 1822) for pristine air cleanliness (Class 100, ISO 5), this unit provides a decorated work space of SS 304-grade stainless steel, ensuring durability and cleanliness. An ultra-low vibration, dynamically balanced blower motor and advanced noise dampening offer comfort with less than 65 dB noise. LED and UV germicidal lighting, transparent acrylic door, and exceptional mobility underscore its supreme utility. Get it now for reliable, efficient air purification in research, pharmaceutical, and microbiology labs.

Unmatched Advantage and Versatility for Diverse Applications

Laminar Flow Apparatus offers a reliable, uncontaminated work area, ideal for laboratory, research, pharmaceutical, and microbiology settings. The apparatus's advanced HEPA filter technology, low noise level, and stainless-steel construction ensure protection for samples and operators. Its spacious, contamination-controlled work surface is suitable for two to three users-making it a value-rich solution for collaborative experiments and quality assurance. Depend on this system for robust air purification, safety, and consistent performance in demanding environments.


Certifications, Packaging, and Streamlined Order Arrival

Each Laminar Flow Apparatus is supported by comprehensive certifications that underscore product valuation and trust. Secure, damage-resistant packaging ensures your order arrives intact and installation-ready. Efficient order processing and FOB port options across India enable quick shipment and timely arrival at your facility. Enjoy a smooth procurement experience, confident that each apparatus meets the highest manufacturing standards and arrives in optimal condition for immediate operation.


FAQ's of Laminar Flow Apparatus:


Q: How does the HEPA filter ensure a contamination-free workspace?

A: The H14-grade HEPA filter traps 99.97% of particles down to 0.3 microns, delivering unassailable air cleanliness (ISO 5, Class 100). This ensures optimal protection for both samples and users.

Q: What applications is the Laminar Flow Apparatus best suited for?

A: This apparatus excels in laboratory, pharmaceutical, microbiology, and research settings, providing reliable air purification and sample integrity for sensitive procedures and experiments.

Q: When is the right time to replace or clean the pre-filter?

A: The washable synthetic fiber pre-filter should be cleaned periodically, especially when the magnehelic pressure gauge indicates increased resistance or after visible dirt accumulation. Replacement is required if the filter is damaged or cannot be effectively cleaned.

Q: Where can the apparatus be positioned for optimal results?

A: With provided caster wheels, the apparatus offers easy mobility and can be positioned wherever a contamination-free environment is needed, typically within laboratory workspaces or cleanrooms.

Q: What is the process for order placement and delivery?

A: Orders are processed through streamlined systems, with secure packaging and FOB port delivery. This ensures safe arrival at your facility, ready for installation and immediate use.

Q: How does the apparatus benefit daily lab operations?

A: It delivers a clean, low-noise, and well-lit work environment, increasing operator comfort, process accuracy, and safety, making it an indispensable value addition for any lab.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Mechanics Lab Category

Hydraulic Bench

Hydraulic Bench

Minimum Order Quantity : 1 Unit

Control Type : Manual control valves

Display Type : Graduated Scale & Digital Timer

Glass Type : Acrylic (for measuring tank window)

Accuracy : 0.5% of reading

Material : Stainless Steel & Acrylic

Experimental Tilting Flume Apparatus

Experimental Tilting Flume Apparatus

Minimum Order Quantity : 1 Unit

Control Type : Manual Tilting Adjustment

Display Type : Analogue (Scale and Pointer)

Glass Type : Transparent Acrylic Sheet

Accuracy : 1 mm (for depth measurement)

Material : Acrylic (Channel), Stainless Steel (Fittings/fasteners)

Losses In Pipe And Fitting  Apparatus

Losses In Pipe And Fitting Apparatus

Minimum Order Quantity : 1 Unit

Control Type : Manual Valve Control

Display Type : Analog Manometer Scale

Glass Type : Borosilicate Glass Manometer Tubes

Accuracy : 1% of Full Scale (Manometers)

Material : Stainless Steel, PVC, Acrylic (Glass Section)

Wind Tunnel Apparatus

Wind Tunnel Apparatus

Minimum Order Quantity : 1 Unit

Control Type : Digital Speed Controller

Display Type : Digital Display

Glass Type : Perspex/Acrylic Observation Window

Accuracy : 1% in air speed measurement

Material : Stainless Steel & Acrylic